Wuhan WTR Expert Technology Co., Ltd.
Automatic Radar Flow Measurement System SCJ-ZDLL01

The SCJ-ZDLL01 automatic radar flow measurement system comprises a cableway tower, an autonomous monitoring vehicle, a radar current meter, a telemetry terminal, a LORA radio, a water level sensor, a power supply system, and a charging station. Designed for low power consumption, the system allows configurable data acquisition intervals and supports continuous online operation, enabling on-demand remote data retrieval.
Classification:
Contact:
Features
● Wide-channel multi-vertical-line dynamic measurement: Supports input of large cross-sectional data with up to 127 measurement points and enables configuration of 64 or more vertical lines (customizable)
● Intelligent cross-section compensation algorithm: Integrates an advanced irregular-section computation model, enabling real-time and accurate calculation of flow area based on dynamic water level data
● High-level intelligence: Achieves fully autonomous operation—from energy management to fault detection and response—ensuring true 7×24-hour unattended monitoring
● Fully automated operation: Equipped with infrared wake-up and position verification functions; measurement tasks can be triggered either on a scheduled basis or dynamically in response to water level fluctuations
● Efficient energy management: Automatically returns to the charging station when battery levels are low and disconnects power upon full charge, optimizing charging cycles and prolonging battery lifespan
● Dual-mode control and redundancy: Supports local serial interface debugging as well as remote configuration, firmware updates, and on-demand data retrieval—measurement commands can even be initiated remotely via mobile devices
● User-friendly local interface: Features a built-in 2.8-inch TFT display and keypad for convenient on-site setup, parameter adjustment, and troubleshooting
● Integrated compatibility and expandability: Seamlessly integrates radar-based surface velocity sensors and non-contact radar water level sensors within a unified system architecture
● Measurement accuracy and operational efficiency: Employs multi-vertical-line dynamic cross-section segmentation technology to effectively address the industry challenge of heterogeneous velocity distribution in wide river channels
● Comprehensive fault diagnosis: Incorporates slip detection, end-limit alarms, and a dual-rail anti-derailment mechanism (with standard rail spacing of 300 mm) to ensure mechanical reliability
● Robust fault-tolerant design: Automatically transitions into a safe standby mode under abnormal conditions, preserving system integrity and enabling rapid recovery
● Environmental adaptability: Engineered for reliable performance in extreme weather conditions, combining a dual-rail anti-derailment structure with non-contact sensing to maintain functionality during high-flow events and adverse environments
● Extended operational endurance: Designed for ultra-low power consumption, ensuring continuous operation unaffected by rain, wind, or grid outages, with dual power support from solar panels and AC mains
● System interoperability: Supports customizable communication protocols for seamless integration into third-party supervisory control and data acquisition (SCADA) or hydrological monitoring platforms
Parameter
| Parameter | Explanation |
| Power supply | DC 12V/24V 2A (limiting DC 6-28V) usually for DC12V 24W power supply |
| Working current | <5.5 mA @ DC12V 25℃ ① |
| Standby current | <0.6mA @ DC12V 25℃ ① |
| Operating Temperature | -30℃-70℃ |
| Storage temperature | -35℃-75℃ |
| RF conductance sensitivity | LTE FDD B1/B3/B5/B8/B34/B38/B39/B40/B41 <-99dBm ② |
| RF output power |
LTE FDD B1/B3/B5/B8 -44dBm ~ 23dBm (±2dBm) LTE TDD B34/38/B39/B40/B41 -42dBm ~ 23dBm (±2dBm) ② |
| Maximum output current | <2A @DC12V (the total current output to the sensor should not exceed 2A) |
| SIM card type | MicroSIM (full Netcom 4G SIM card) |
| Display screen | 2.8 inch TFT LCD 320*240 resolution |
| Short pass method | Wireless Lora |
| Transmission mode | Ethernet /4G/or 2G/3G/5G/WIFI |
| Waking method | Infrared wake-up, LORA air wake-up |
| Measurement method | Timed, triggered, on-demand |
Autonomous monitoring vehicle
| Battery parameters | 18.5V 20AH lithium battery |
| Charging voltage | DC24~28V |
| Charging current | <1.2A |
| Charging method | Automatic constant current and constant voltage charging with the capability to actively terminate the charging process. |
| Limiting method | Limit photoelectric sensing, charging position sensing |
| Operating Temperature | -30℃-65℃ |
| Wheel Gauge | 300mm |
| Transmission mode | Wireless Lora or 2.4G |
| Waking method | Infrared wake-up, LORA air wake-up |
| Current meter interface | DC12V RS485 |
| Communication distance | ≥3000m |
| Position accuracy | > 0.1% |
| Ingress Protection Rating | IP45 |
| Wind Resistance Class | Class 8 |
| Motor Power | ≤40W |
| Other functions | Slip detection, abnormal charging alarm, fault alarm |
| Size | 474x325x112mm |
Radar current meter
| Power supply | DC 12V/24V (limit DC 9-28 V) Recommended DC12V |
| Working current | Average current < 18 mA @ DC12V, 25℃ ① |
| Operating temperature | -30℃~70℃ |
| Storage temperature | -40℃~85℃ |
| Flow velocity range | 0 - 65 m/s (Settable range: 0 - 18 m/s; 0 - 36 m/s; 0 - 65 m/s), default: 0 - 18 m/s ② |
| Flow velocity accuracy | 1% (±1cm/s with 1 m) |
| Flow velocity resolution | 1mm/s |
| Waterproof grade | IP68 |
| Power supply protection | Anti-reverse connection protection, ESD protection |
| Limiting operating temperature | -35℃~80℃ |
| Communication interface | RS485 interface (baud rate 9600, 8, N, 1), effective transmission distance 1000m (external 150 Ω matching resistor is required for > 300m) ③ |
| Communication protocol | Standard Modbus-RTU protocol, function code 03H |
| Flow measurement radar frequency | 24GHz |
| Flow measurement antenna beam angle | Horizontal 12°, vertical 25° |
| Size | 100x100x38mm |
| weight | 0.55Kg(Excluding cables and brackets) |
Application Case
FAQ
Q
Q: Are you trading company or manufacturer ?
+
A
A: We are a manufacturer, committed to producing high accuracy, long-term stability, cost-efficient pressure/ level/ temperature measuring instruments.
Q
Q: What's your quality control system?
+
A
A: All of our products are completed with inspection before shipment. And all of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO, we could send the certification test of our company to you.
Q
Q: What is the warranty of your products?
+
A
A: 2 years for level transmitter and pressure transmitter series others are 5 years from shipment date, for non-man-made damages.
Q
Q: What is your shipping method?
+
A
A: Small orders are delivered with DHL, FedEx, TNT, UPS , EMS. Large orders are recommended to ship by sea.
Q
Q: Do you provide samples ?
+
A
A: Yes,we have materials in stock to help you to get the samples as soon as we can.
Q
Q: How long will you give me the reply?
+
A
A: We can support you 24Hours online service via email, skype, what'sapp, facebook etc within 1 hour.
Leave Message
If you have already experienced our product, please let us know your true feelings. Your satisfaction is our driving force for progress, while your suggestions are our valuable asset for continuous improvement.
Contact Us
Contact Us
Add: Lianxiang Enterprise Center, No.11 Fenghuang Avenue, Canglong lsland, Jiangxia Distrlct, Wuhan City Hubei Province
在线客服添加返回顶部
右侧在线客服样式 1,2,3 1
图片alt标题设置: Wuhan WTR Expert Technology Co., Ltd.
表单验证提示文本: Content cannot be empty!
循环体没有内容时: Sorry,no matching items were found.
CSS / JS 文件放置地